Add to Cart
Energy Saving Closed Cooling Tower With Seamless 316L SS Cooling Coils
WORKING PRINCIPLE
1,Working fluid (water, oil o other liquid) flowing inside of the coils, which is enwrapped by spray water on the outside. The heat of water is transferred by coil and become the saturated vapor when meet the water and air.
2, the heat is exhausted out of the tower by the tower by the top fan; water is collected back to the bottom tank and circulates continuously. The spray water is cooled down via PVC radiation fin in the process of circulation, and flow is the same direction with the fresh wind. The coil mainly takes sensible heat travel style.
3, the most benefit of this style is can avoid scale formation on the outside of the coil. And this will apply especially to dealing with high temperature fluid (e.g. 60°C) or the fluid need big temperature difference (e.g. 60°C to 32°C).
Item
FBN-300T Specifications | |
Heat Reject | 1635kw |
Nominal Flow Rate | 300 m3/h |
Work Flow Rate | 235 m3/h |
Fan Power | 2×11kw |
Wind Flow Rate | 2×120000m3/h |
Spray Pump Power | 7.5kw |
Spray Water Flow Rate | 172m3/h |
Spray Pump Raise | 9.6m |
Inlet/Outlet Diameter | DN 200mm |
Makeup Connection | DN40 (Please specify adopted screw standards) |
Bleed Line Diameter | DN50 (Please specify adopted screw standards) |
Net Weight | 5150kg |
Operate Weight | 9500kg |
Dimensions | 5100×2300×4950mm |
Main Features
1) Whole suit, it will convenient for customers to operate, and easy to transportation & installation..
2) structure is compact, installation area is less, and also more space is saved to enlarge the coils’ unit heat rejection area.
3) Energy efficient and environmental protection.Running in a high automatization and intellectualization,no pollution.
4) apply to the low cooling temperature(Temp.<45℃ or not higher than the location wet bulb temperature too much )or needs a small cooling range projects (△T=5-10℃)
5) Professional and serious attitude, and attention to detail is the pursuit of supremacy consistent high quality standards, production, products and services. This COUNTER FLOW mini cooling towerused for smelting furnace.
Product Application
1. Cooling Tower +Heat Exanger Combination
Closer approach to wet bulb temperature and reduce fouling, highly improve process efficiency
2. Air-Cooled Systems
10-20°C lower process temperatures ,less required space and lower energy consumption
3. Once –Through Systems
Reduces environmental impact ,saving up to 95% of the cooling water
4. Reduced installed Cost And Space Requirements
Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity.